How to deal with the heat pump for swimming pool water flow protection?

Most of the heat pump for swimming pools usually have a water flow switch protection program, because whether there is water flow is also a necessary condition for the pool heater to start. The purpose is to prevent the failures such as only water pump operation but compressor not work, water shortage operation, and condenser high temperature, so as to ensure the normal operation of the pool heater for above ground pool.

 

But when the heat pump for swimming pool has water flow switch protection, what cause the protection?

1. Water flow switch installation of the pool heater is not standard or the direction is incorrect

2. Air in water system pipeline of the heat pump for swimming pool

3. Water system filter of the pool heater is blocked

4. Water system of the pool heater lack of water

5. Something wrong with the water flow switch of the heat pump for swimming pool

6. Wiring connection of the water flow switch of the heat pump for swimming pool is incorrect

7. Water flow switch blade of the pool heater for above ground pool is too long and thus stuck in the pipeline

8. Something wrong with the water pump of the pool heater for above ground pool

9. Pump water flow of the pool heater is small

10. Water pump of the pool heater is not working

 

Related solutions:

1. Correct the installation of the water flow switch of the pool heater, adjust its direction

2. Open the vent valve to clear out the air in pipeline

3. Clean the filter and the pipeline of the pool heater

4. Feed water and clear out the air in pipeline

5. Replace the water flow switch of the heat pump for swimming pool

6. Correct the wiring connection of water flow switch of the heat pump for swimming pool

7. Adjust the length of the blade of the heat pump for swimming pool and install correctly

8. Replace the water pump of the pool heater for above ground pool

9. Replace the water pump of the pool heater for above ground pool according to water flow and pump lift required for the system

10. Investigate the cause and clear the failure of the pool heater for above ground pool

 

FANTASTIC factory has a complete heat pump industrial manufacturing chain from product cabinet to a complete heat pump system, not only abides by ISO9001 International Quality Standard, but also owns full-computer automatic monitoring production lines. Please consult the FANTASTIC heat pump manufacturer for more information!

 

 

660

shares

contact us

contact-email
contact-logo

FANTASTIC ENERGY-SAVING EQUIPMENT CO., LTD.

We provide customers with quality products and services.

看不清,请点击我!

If you would like to leave us a comment please go to contact us

top